Laser direct imaging systems

MX-1205

A maskless exposure system from Dainippon Kaken. A DMD from TI generates the exposure pattern, and the company's own point array method, using a microlens array and oblique scanning, writes the pattern directly. It is aimed at R&D, prototyping and small-lot production.

Maker: Dainippon Kaken · Official product page

Dainippon Kaken
  • Free to useQuotes and inquiries are free of charge
  • Phone number is optionalYou can send the form without it
Official product page ↗
How it works
  1. Fill in the form and send itEnter your company name, contact name, email address and request. Phone, quantity and timing are optional.
  2. Semirai forwards your requestSemirai receives your request and forwards it to Dainippon Kaken. Your details are shared with the maker only with your consent.
  3. The maker repliesReplies usually arrive within 2–3 business days.

Can't find a product, or unsure which to choose?

Free consultation

Specifications


TypeDMD-based maskless exposure (point array method)
Minimum line width2 μm / 1 μm
Maximum substrate size100 × 100 mm
Main wavelength375 nm
Main applicationsR&D, prototyping and small-lot production

Specifications as published by the maker. See the sources below.

Overview


MX-1205 is a maskless exposure system from Dainippon Kaken. It is the model with the finest line width in the company's MX series (MX-1201 / MX-1201E / MX-1205). The minimum line width comes in 2 versions, 2 µm and 1 µm, with data resolutions of 0.1 µm and 0.05 µm respectively.

In the company's point array method, a DMD made by Texas Instruments generates the exposure pattern, and a microlens array focuses the light from each pixel into a spot. Scanning with the spot array set at an angle gives a data resolution far smaller than the DMD pixels. Because no photomask is needed, development costs and time to market can be reduced.

The maximum substrate size and effective exposure area are 100 × 100 mm, and the main wavelength is 375 nm. Exposure scan speeds are 9 mm/s and 4.5 mm/s, and takt times are 16 minutes and 27 minutes (excluding alignment time).

Key features


  • Finest line width in the MX series: 2 µm / 1 µm
  • Data resolution of 0.1 µm / 0.05 µm
  • Point array method using a DMD and microlens array
  • Direct-imaging exposure with no photomask

Applications


  • R&D and prototyping of semiconductors and MEMS
  • Small-lot production of high-density packaging and electronic components

FAQ


Will the minimum line width always be 1 µm?

Dainippon Kaken states that the minimum line width depends on the photoresist used, film thickness, development conditions and other factors.