VOX6001 / HiVOX6001
An oxidation system for fabricating vertical-cavity surface-emitting lasers (VCSELs). HiVOX6001 has a real-time monitor, and substrates from Φ6 inch × 1 to Φ2 inch × 7 are supported.
Maker: EpiQuest · Official product page
- Free to useQuotes and inquiries are free of charge
- Phone number is optionalYou can send the form without it
How it works
- Fill in the form and send itEnter your company name, contact name, email address and request. Phone, quantity and timing are optional.
- Semirai forwards your requestSemirai receives your request and forwards it to EpiQuest. Your details are shared with the maker only with your consent.
- The maker repliesReplies usually arrive within 2–3 business days.
Can't find a product, or unsure which to choose?
Free consultationSpecifications
| Substrate size | Φ6 inch × 1, Φ4 inch × 1, Φ3 inch × 3, Φ2 inch × 7 |
|---|---|
| Substrate heating | Resistance heating, up to 600 °C (control thermocouple value) |
| Source supply system | Liquid mass flow controller, thermal vaporizer (max. 180 °C) |
| Oxidation performance (oxidation width) | In-plane uniformity 10 μm ±0.4 μm (excluding periphery), reproducibility 10 μm ±0.4 μm (run to run) |
Specifications as published by the maker. See the sources below.
Overview
VOX6001/HiVOX6001 is EpiQuest's oxidation system for fabricating vertical-cavity surface-emitting lasers. HiVOX6001 is the model with a real-time monitor. Supported substrate sizes are Φ6 inch × 1, Φ4 inch × 1, Φ3 inch × 3 and Φ2 inch × 7.
Substrate heating is by resistance heating, up to 600 °C (control thermocouple value). The source supply system uses a liquid mass flow controller and a thermal vaporizer (max. 180 °C), the vacuum pumping system uses a diaphragm pump, and the control unit is a sequence controller for interlocks.
Oxidation performance (oxidation width) is 10 μm ±0.4 μm in-plane uniformity (excluding periphery) and 10 μm ±0.4 μm reproducibility (run to run), and depends on the characteristics of the AlAs epitaxial layer. A loader/unloader is available as an option.
Key features
- HiVOX6001 has a real-time monitor
- Supports substrates from Φ6 inch × 1 to Φ2 inch × 7
- Source supply with a liquid mass flow controller and a thermal vaporizer
- Optional loader/unloader
Applications
- Oxidation step in vertical-cavity surface-emitting laser (VCSEL) fabrication
FAQ
How uniform is the oxidation width?
According to the official specifications, in-plane uniformity is 10 μm ±0.4 μm (excluding periphery) and run-to-run reproducibility is 10 μm ±0.4 μm. These figures depend on the characteristics of the AlAs epitaxial layer.
Terms explained
Oxide Film (Silicon Dioxide) · LOCOS (Local Oxidation of Silicon)
Other oxidation furnaces
- VERTEX Revolution · Kokusai Electric
- VF-3000 · Koyo Thermo Systems (JTEKT Thermo Systems)
- VF-3000B · Koyo Thermo Systems (JTEKT Thermo Systems)
- VF-5300H · Koyo Thermo Systems (JTEKT Thermo Systems)
- TELINDY PLUS · Tokyo Electron (TEL)
More from EpiQuest
- HTC3001 · CVD equipment
- MPC6100 · MOCVD equipment
- RC1100 · Molecular beam epitaxy (MBE) equipment
- SH series · MOCVD equipment
- SV series / SVS series · MOCVD equipment
Sources
Oxidation furnaces
Last updated: November 13, 2026