VOX6001 / HiVOX6001
An oxidation system for fabricating vertical-cavity surface-emitting lasers (VCSELs). HiVOX6001 has a real-time monitor, and substrates from Φ6 inch × 1 to Φ2 inch × 7 are supported.
| Substrate size | Φ6 inch × 1, Φ4 inch × 1, Φ3 inch × 3, Φ2 inch × 7 |
|---|---|
| Substrate heating | Resistance heating, up to 600 °C (control thermocouple value) |
| Source supply system | Liquid mass flow controller, thermal vaporizer (max. 180 °C) |
| Oxidation performance (oxidation width) | In-plane uniformity 10 μm ±0.4 μm (excluding periphery), reproducibility 10 μm ±0.4 μm (run to run) |