PHI 710
A scanning Auger electron spectroscopy system (AES/SAM) with a guaranteed Auger electron spatial resolution of 8 nm or better. It comes standard with an acoustic enclosure and performs Auger analysis of nanometer-scale areas.
Maker: ULVAC-PHI · Official product page
- Free to useQuotes and inquiries are free of charge
- Phone number is optionalYou can send the form without it
How it works
- Fill in the form and send itEnter your company name, contact name, email address and request. Phone, quantity and timing are optional.
- Semirai forwards your requestSemirai receives your request and forwards it to ULVAC-PHI. Your details are shared with the maker only with your consent.
- The maker repliesReplies usually arrive within 2–3 business days.
Can't find a product, or unsure which to choose?
Free consultationSpecifications
| Type | Scanning Auger electron spectroscopy system (AES/SAM) |
|---|---|
| Resolution | SEM resolution ≤3 nm, AES resolution ≤8 nm (20 kV, 1 nA) |
| Analyzer | Coaxial cylindrical mirror analyzer (CMA) |
| Configuration | Acoustic enclosure as standard |
Specifications as published by the maker. See the sources below.
Overview
PHI 710 is ULVAC-PHI's scanning Auger electron spectroscopy system (AES/SAM). The official site describes it as the world's only Auger analysis system that guarantees an Auger electron spatial resolution of 8 nm or better.
Lower-noise power supplies give an SEM resolution of 3 nm or better, and a standard acoustic enclosure limits the effects of vibration, sound, and temperature changes. This allows low-drift Auger analysis at 500,000x magnification, with analysis at a resolution of 8 nm (20 kV, 1 nA) or better.
Its analyzer is a coaxial CMA with the electron gun on the central axis. Because it collects Auger electrons emitted in all directions over 360 degrees, the company says it is less affected by sample shape and tilt angle. Spectrum maps that keep the spectrum for each pixel enable chemical state mapping, and a measurement example shows elemental Si, Si oxynitride, and metal silicide separated on a semiconductor chip electrode.
Key features
- SEM resolution ≤3 nm, AES resolution ≤8 nm
- Low-drift analysis with a standard acoustic enclosure
- High-sensitivity, high-throughput analysis with a coaxial cylindrical mirror analyzer (CMA)
- Chemical state mapping with spectrum maps
Applications
- Spectrum, depth, and map measurements of small areas identified by SEM observation
- Chemical state mapping of semiconductor chip electrodes (an official measurement example)
- Auger analysis of samples with complex shapes
FAQ
What is special about the PHI 710 analyzer?
The official site explains that the coaxial CMA collects Auger electrons emitted in all directions over 360 degrees, so it is less affected by sample shape and tilt angle and gives sensitivity with little angle dependence.
Other surface analysis instruments (xps/sims)
- GD-Profiler 2™ · HORIBA
- JAMP-9510F · JEOL
- JPS-9030 · JEOL
- TXRF 3760 · Rigaku
- KRATOS ULTRA2 (AXIS Supra+) · Shimadzu
- PHI ADEPT 2 · ULVAC-PHI
- PHI GENESIS · ULVAC-PHI
All surface analysis instruments (xps/sims) and Japanese suppliers
More from ULVAC-PHI
- PHI nanoTOF 3+ · Contamination analysis equipment
Sources
Surface analysis instruments (XPS/SIMS)
Last updated: November 13, 2026