XGT-9000
HORIBA's X-ray analytical microscope (micro-XRF). It images elemental distribution and internal structure simultaneously with 2 detectors, one for fluorescent X-rays and one for transmitted X-rays, and is used for failure analysis of foreign particles and film thickness measurement.
Maker: HORIBA · Official product page
- Free to useQuotes and inquiries are free of charge
- Phone number is optionalYou can send the form without it
How it works
- Fill in the form and send itEnter your company name, contact name, email address and request. Phone, quantity and timing are optional.
- Semirai forwards your requestSemirai receives your request and forwards it to HORIBA. Your details are shared with the maker only with your consent.
- The maker repliesReplies usually arrive within 2–3 business days.
Can't find a product, or unsure which to choose?
Free consultationSpecifications
| Type | Energy-dispersive micro X-ray fluorescence analysis (μ-XRF) |
|---|---|
| X-ray beam diameter | 10 µm to 1.2 mm (depends on probe) |
| Sample chamber | 450 mm (W) × 500 mm (D) × 80 mm (H) |
| Maximum mapping area | 100 mm × 100 mm |
Specifications as published by the maker. See the sources below.
Overview
XGT-9000 is HORIBA's energy-dispersive X-ray analytical microscope (micro-XRF). It performs elemental analysis and elemental imaging without damaging the sample. Besides the standard XGT-9000, there is the XGT-9000 Pro with higher sensitivity and the XGT-9000 Expert with the widest range of detectable elements.
A fluorescent X-ray detector images elemental distribution while a transmitted X-ray detector images internal structure at the same time. Probes are switched in software, and ultra-high-intensity probes of 15 µm and 100 µm are available. The X-ray tube has an Rh target rated at up to 50 kV and 1 mA, and the fluorescent X-ray detector is an SDD that needs no liquid nitrogen.
The sample chamber measures 450 mm (W) × 500 mm (D) × 80 mm (H), and mapping covers an area of up to 100 mm × 100 mm. In semiconductors and electronic components, it is used for quality control of fine patterns, film thickness measurement, failure analysis of ion migration, voids and foreign particles, and plating analysis.
Key features
- Simultaneous imaging with fluorescent and transmitted X-rays
- Ultra-high-intensity probes of 15 µm and 100 µm
- SDD detector that needs no liquid nitrogen
- Large sample chamber and mapping up to 100 mm square
Applications
- Elemental analysis and failure analysis of foreign particles and contaminants
- Thin-film thickness measurement and plating (Ni/P/Au) analysis
- RoHS screening
Other contamination analysis equipment
- JAMP-9510F · JEOL
- K-TRX · Kowa Thermo Technologies & Products
- TXRF-V310 · Rigaku
- XHEMIS TX-2000 · Rigaku
- XHEMIS TX-3000 · Rigaku
- ICPMS-2050 · Shimadzu
- PHI nanoTOF 3+ · ULVAC-PHI
More from HORIBA
- Auto SE · Ellipsometers
- CRITERION D500 · Mass flow controllers (MFC)
- GD-Profiler 2™ · Surface analysis instruments (XPS/SIMS)
- LabRAM Odyssey Semiconductor · Organic analysis instruments
- MiPLATO-SiC · SiC power semiconductor equipment
- PD10-EX · Mask inspection equipment
- PLATO-MicroScan · Compound semiconductor equipment
- PLATO Series · Crystal defect inspection equipment
Sources
Contamination analysis equipment
Last updated: November 13, 2026