Exhibiting at SEMICON Japan 2026 (Dec 9–11)? We are now accepting advertising inquiries from exhibitors.Ads for SEMICON Japan 2026Learn more

Inspection and metrology equipment

Contamination analysis equipment6 Japanese makers

Contamination analysis equipment identifies the elemental composition and origin of particles and surface contamination found by inspection tools. SEM-EDX analyzes individual particles, total reflection X-ray fluorescence (TXRF) measures metal contamination on wafer surfaces, and ICP-MS quantifies trace metals in chemicals and collected solutions.

8 products listed · 12 related categories
Get quotes (7 companies)Inquire (7 companies)

Tick "Add to bulk request" on the cards to send your request only to the companies and products you choose.

  • Free to useQuotes and inquiries are free of charge
  • Phone number is optionalYou can send the form without it
How it works
  1. Fill in one form and send itEnter your company name, contact name, email address and request. Phone, quantity and timing are optional.
  2. Semirai forwards your requestSemirai receives your request and forwards it to the 7 companies in this category. Your details are shared with them only with your consent.
  3. The companies replyEach company usually replies within 2–3 business days.

AdBanner space for Contamination analysis equipment is available (one company per category).About advertising →

HORIBA

XGT-9000

HORIBA's X-ray analytical microscope (micro-XRF). It images elemental distribution and internal structure simultaneously with 2 detectors, one for fluorescent X-rays and one for transmitted X-rays, and is used for failure analysis of foreign particles and film thickness measurement.

TypeEnergy-dispersive micro X-ray fluorescence analysis (μ-XRF)
X-ray beam diameter10 µm to 1.2 mm (depends on probe)
Sample chamber450 mm (W) × 500 mm (D) × 80 mm (H)
Maximum mapping area100 mm × 100 mm
JEOL

JAMP-9510F

An Auger microprobe with a hemispherical analyzer and a Schottky field emission electron gun. It analyzes chemical bonding states in nano to micro areas.

Analysis techniqueAES (Auger electron spectroscopy)
Key featureMinimum probe diameter 8 nm in Auger analysis, image resolution 3 nm, up to 200 nA
Main applicationsComposition and chemical state analysis of small areas
Kowa Thermo Technologies & Products

K-TRX

Kowa Thermo Technologies & Products' metal contamination measurement system, which uses X-rays to measure metal contamination on semiconductor wafers, glass substrates and similar workpieces. X-rays strike the surface at a grazing angle and undergo total reflection while fluorescent X-rays are measured.

TypeTotal reflection X-ray fluorescence (X-rays strike the workpiece at a grazing angle)
Measurement targetsMetal contamination on semiconductor wafers, glass substrates and similar workpieces
X-ray sourcesAvailable for light, transition and heavy elements
DetectorX-ray detector without liquid nitrogen
Rigaku

TXRF-V310

A total reflection X-ray fluorescence spectrometer with integrated vapor phase decomposition (VPD) pretreatment. It measures trace metal contamination on wafer surfaces from Na to U, and Rigaku claims a detection limit of 1E7 atoms/cm² when VPD is used.

TypeTotal reflection X-ray fluorescence (TXRF) + vapor phase decomposition (VPD)
Supported wafers300 mm, 200 mm, 150 mm
Elements measuredNa to U
X-ray source9 kW rotating anode (W target), 3-beam excitation
ConfigurationDual FOUP load ports, in-vacuum wafer transfer robot, XYθ stage
Rigaku

XHEMIS TX-2000

Rigaku's total reflection X-ray fluorescence (TXRF) system. The successor to the TXRF 3760, it quantifies ultra-trace metal contamination on the surface of 100 to 200 mm wafers non-destructively.

TypeTotal reflection X-ray fluorescence (TXRF)
Supported wafersSi, SiC, GaN, glass, sapphire; 100 mm to 200 mm maximum
Detection limitE9 atoms/cm² for transition metals (typical)
Main unit dimensionsApprox. 1050 (W) × 2020 (H) × 1025 (D) mm
Rigaku

XHEMIS TX-3000

A total reflection X-ray fluorescence spectrometer optimized for advanced processes. Simultaneous multipoint measurement with a 3-detector configuration analyzes trace metal contamination on wafer surfaces for wafers up to 300 mm.

TypeTotal reflection X-ray fluorescence (TXRF)
Supported wafersUp to 300 mm
Elements measuredNa to U
Configuration3-detector configuration (multi-element detector), 9 kW rotating-anode X-ray source, XYθ stage
Main functionsSweeping-TXRF (full-wafer mapping), ZEE-TXRF (zero edge exclusion)
Shimadzu

ICPMS-2050

The high-sensitivity model of Shimadzu's ICP mass spectrometers for qualitative and quantitative analysis of inorganic elements. A new mechanism that removes unwanted ions raises sensitivity for specific elements.

Analysis techniqueICP-MS (inductively coupled plasma mass spectrometry)
Analysis targetsTrace inorganic elements in liquids
Key featureAbout twice the sensitivity of the earlier model; mini torch cuts Ar consumption to about 2/3
Main applicationsAnalysis of metal impurities in chemicals and ultrapure water
ULVAC-PHI

PHI nanoTOF 3+

A time-of-flight secondary ion mass spectrometer (TOF-SIMS) that brings in fully automatic analysis technology developed for XPS. It automates everything from sample transfer to measurement.

Analysis techniqueTOF-SIMS (time-of-flight secondary ion mass spectrometry)
Analysis targetsOrganic and inorganic surface contamination (small areas)
Key featureSpatial resolution 50 nm (high spatial resolution mode), fully automatic analysis
Main applicationsSurface contamination and composition analysis of semiconductors and battery materials

* Specifications are reference values based on public information. Please confirm exact specifications with the maker.

Other inspection and metrology equipment


Sources


  1. HORIBA: XGT-9000 product page
  2. JEOL: JAMP-9510F product page
  3. Kowa Thermo Technologies & Products: X-ray measurement equipment page (metal contamination measurement system K-TRX)
  4. Rigaku: TXRF-V310 product page
  5. Rigaku: XHEMIS TX-2000 product page
  6. Rigaku: XHEMIS TX-3000 product page
  7. Shimadzu: ICPMS-2040/2050 product page
  8. ULVAC-PHI: PHI nanoTOF 3 product page

More on this topic


Japanese equipment by category

Contamination analysis equipment

Last updated: November 13, 2026