Exhibiting at SEMICON Japan 2026 (Dec 9–11)? We are now accepting advertising inquiries from exhibitors.Ads for SEMICON Japan 2026Learn more

Contamination analysis equipment

TXRF-V310

A total reflection X-ray fluorescence spectrometer with integrated vapor phase decomposition (VPD) pretreatment. It measures trace metal contamination on wafer surfaces from Na to U, and Rigaku claims a detection limit of 1E7 atoms/cm² when VPD is used.

Maker: Rigaku · Official product page

Rigaku
  • Free to useQuotes and inquiries are free of charge
  • Phone number is optionalYou can send the form without it
Official product page ↗
How it works
  1. Fill in the form and send itEnter your company name, contact name, email address and request. Phone, quantity and timing are optional.
  2. Semirai forwards your requestSemirai receives your request and forwards it to Rigaku. Your details are shared with the maker only with your consent.
  3. The maker repliesReplies usually arrive within 2–3 business days.

Can't find a product, or unsure which to choose?

Free consultation

Specifications


TypeTotal reflection X-ray fluorescence (TXRF) + vapor phase decomposition (VPD)
Supported wafers300 mm, 200 mm, 150 mm
Elements measuredNa to U
X-ray source9 kW rotating anode (W target), 3-beam excitation
ConfigurationDual FOUP load ports, in-vacuum wafer transfer robot, XYθ stage

Specifications as published by the maker. See the sources below.

Overview


TXRF-V310 is a contamination analysis system that builds a vapor phase decomposition (VPD) pretreatment unit into Rigaku's total reflection X-ray fluorescence (TXRF) spectrometer. It is intended for evaluating metal contamination on wafer surfaces in processes such as cleaning, lithography, etching, ashing and deposition.

VPD collects and concentrates trace contamination from the wafer surface before TXRF measurement, which gives a lower detection limit than TXRF alone. A table on the official page lists detection limits for Fe and Ni at a 1000-second measurement of 0.10E10 atoms/cm² with TXRF and 0.001E10 atoms/cm² with VPD-TXRF. It also supports parallel processing, measuring another wafer by TXRF while VPD treatment of a wafer is in progress.

Key features


  • Runs VPD pretreatment and TXRF measurement in one system, allowing integrated control in factory automation
  • 9 kW rotating-anode X-ray source and 3 excitation energies cover light to heavy elements
  • Detector that needs no liquid nitrogen
  • Options include full-wafer mapping (Sweeping-TXRF), zero edge exclusion (ZEE-TXRF) and backside measurement (BAC-TXRF)

Applications


  • Monitoring of metal contamination on wafer surfaces after cleaning, etching and deposition
  • Elemental analysis of particles using coordinates imported from defect inspection systems
  • VPD analysis of wafers with hydrophilic surfaces such as SiC

FAQ


Which wafer sizes does TXRF-V310 support?

According to the official page, it supports 300 mm, 200 mm and 150 mm wafers. The 200 mm load port is optional.

Other contamination analysis equipment


All contamination analysis equipment and Japanese suppliers

More from Rigaku


  • AZX 400 · Film composition analysis (XRF/FTIR)
  • FSAS II · Wafer substrate inspection equipment
  • FSAS III · Wire saws and wafer slicing equipment
  • ONYX 3200 · Film composition analysis (XRF/FTIR)
  • TFXRD Lab · Film composition analysis (XRF/FTIR)
  • TXRF 3760 · Surface analysis instruments (XPS/SIMS)
  • WaferX 310 · Film composition analysis (XRF/FTIR)
  • WDA-3650 · Film composition analysis (XRF/FTIR)

Sources


  1. Rigaku: TXRF-V310 product page

More on this topic


Last updated: November 13, 2026