HyperGauge C17319-11
An areal film thickness gauge based on spectral interferometry that uses λ-Capture technology, in which a high-sensitivity camera captures wavelength shifts. It acquires the film thickness distribution across a full φ300 mm wafer in about 5 seconds.
Maker: Hamamatsu Photonics · Official product page
- Free to useQuotes and inquiries are free of charge
- Phone number is optionalYou can send the form without it
How it works
- Fill in the form and send itEnter your company name, contact name, email address and request. Phone, quantity and timing are optional.
- Semirai forwards your requestSemirai receives your request and forwards it to Hamamatsu Photonics. Your details are shared with the maker only with your consent.
- The maker repliesReplies usually arrive within 2–3 business days.
Can't find a product, or unsure which to choose?
Free consultationSpecifications
| Type | Spectral interferometry (λ-Capture analysis) |
|---|---|
| Film thickness range | 10 nm to 1000 nm |
| Field of view | Full φ300 mm wafer |
| Spatial resolution | 0.3 mm/pixel |
| Measurement time | 5 s (including analysis; depends on measurement and analysis conditions) |
Specifications as published by the maker. See the sources below.
Overview
HyperGauge C17319-11 is an areal film thickness gauge from Hamamatsu Photonics. It works on the principle of spectral interferometry but uses no spectrometer. Instead, its λ-Capture technology detects wavelength shifts with a high-sensitivity camera. Its key feature is measuring film thickness across a full 300 mm wafer at once.
According to the company, it acquires the in-wafer film thickness distribution from about 750,000 measurement points in 5 seconds. Unlike point sensors, it images the whole wafer at once, which the company says makes choosing measurement points and alignment easier. It handles both bare wafers and patterned wafers.
The film thickness range is 10 nm to 1000 nm. Measurement accuracy is ±1 nm for 10 nm to 100 nm films and ±1 % for 100 nm to 1000 nm films. Spatial resolution is 0.3 mm/pixel, and external communication supports Camera Link and RS-232C.
Key features
- Areal measurement with λ-Capture technology, without a spectrometer
- Acquires in-wafer thickness distribution from about 750,000 points in 5 seconds
- Images a full φ300 mm wafer at once
- Handles both bare wafers and patterned wafers
Applications
- Controlling in-wafer film thickness uniformity in semiconductor manufacturing
FAQ
How accurate is it?
According to the official specifications, accuracy is ±1 nm for 10 nm to 100 nm films and ±1 % for 100 nm to 1000 nm films. Repeatability with 96 accumulations is 0.1 nm for 10 nm to 100 nm and ±0.1 % for 100 nm to 1000 nm.
Terms explained
Uniformity (Within-Wafer and Wafer-to-Wafer) · Ellipsometry (Spectroscopic Ellipsometry)
Other film thickness metrology
- Optical NanoGauge C12562-03 · Hamamatsu Photonics
- Xtrology · HORIBA
- UTS-2000 series · JASCO
- K-MSX · Kowa Thermo Technologies & Products
- GS-300 · Otsuka Electronics
- OPTM series · Otsuka Electronics
- XHEMIS EX-2000 · Rigaku
- VM-1020 · SCREEN Holdings
More from Hamamatsu Photonics
- Plasma process monitor C10346-01 · Process monitors (EPD/OES)
- Dual PHEMOS®-X C16506-01 · Failure analysis equipment
- iPHEMOS®-DDX C18040-11 · Failure analysis equipment
- iPHEMOS-MPX C10506-07-06 · Failure analysis equipment
- L12531-01 · X-ray inspection systems (2D and CT)
- Photoionizer L12645 · Ionizers (static elimination)
- MiNY PL C15740-01 · Optical wafer inspection equipment
- Optical MicroGauge C11011 Series · Wafer flatness and thickness metrology
Sources
Last updated: November 13, 2026