XHEMIS EX-2000
Rigaku's X-ray film thickness and density measurement system. It combines X-ray fluorescence (XRF) and X-ray reflectometry (XRR) to measure the thickness and density of various thin films on wafers without contact or damage.
Maker: Rigaku · Official product page
- Free to useQuotes and inquiries are free of charge
- Phone number is optionalYou can send the form without it
How it works
- Fill in the form and send itEnter your company name, contact name, email address and request. Phone, quantity and timing are optional.
- Semirai forwards your requestSemirai receives your request and forwards it to Rigaku. Your details are shared with the maker only with your consent.
- The maker repliesReplies usually arrive within 2–3 business days.
Can't find a product, or unsure which to choose?
Free consultationSpecifications
| Type | X-ray fluorescence (XRF) + X-ray reflectometry (XRR) |
|---|---|
| Throughput | XRR measurement 15 to 25 WPH |
| Supported wafers | 200 mm to 100 mm (open cassette automatic transfer, optional) |
| Main applications | Thickness and density measurement for FEOL (CoSix, NiSix, SiGe, high-κ films, etc.) and BEOL (barrier metals, Ta/TaN, Ti/TiN, Cu seed, Cu plating, W, etc.) |
Specifications as published by the maker. See the sources below.
Overview
XHEMIS EX-2000 is Rigaku's X-ray film thickness and density measurement system. Using X-ray fluorescence (XRF) and X-ray reflectometry (XRR), it measures the thickness and density of various thin films on wafers without contact or damage. Combining XRR and XRF is said to allow thickness measurement over a wide range without reference samples.
Newly developed optics with a high-speed detector achieve a throughput of 15 to 25 WPH for XRR measurement. Rigaku says special (patented) signal processing produces low-noise spectra with high dynamic range.
It has angle adjustment using X-ray reflection and fast Z-axis alignment, and supports mapping measurement over the whole wafer. Open cassette automatic transfer of 200 mm to 100 mm wafers and SECS communication with the host are options.
Key features
- High-throughput, high-dynamic-range XRR measurement with new optics and signal processing
- Angle adjustment using X-ray reflection shortens alignment time
- AutoCal function performs routine maintenance of optics, X-ray source and detector fully automatically
- XRR thickness and density analysis software that requires no complex analysis
Applications
- Thickness and density measurement of FEOL thin films (CoSix, NiSix, SiGe, high-κ films, Al, etc.)
- Thickness and density measurement of BEOL thin films (barrier metals, Ta/TaN, Ti/TiN, Cu seed, Cu plating, W, etc.)
- Thin-film evaluation from R&D to quality control
FAQ
Does XHEMIS EX-2000 need reference samples?
The official page explains that combining XRR and XRF allows thickness measurement over a wide range without reference samples.
Terms explained
Uniformity (Within-Wafer and Wafer-to-Wafer) · Ellipsometry (Spectroscopic Ellipsometry)
Other film thickness metrology
- HyperGauge C17319-11 · Hamamatsu Photonics
- Optical NanoGauge C12562-03 · Hamamatsu Photonics
- Xtrology · HORIBA
- UTS-2000 series · JASCO
- K-MSX · Kowa Thermo Technologies & Products
- GS-300 · Otsuka Electronics
- OPTM series · Otsuka Electronics
- VM-1020 · SCREEN Holdings
More from Rigaku
- AZX 400 · Film composition analysis (XRF/FTIR)
- FSAS II · Wafer substrate inspection equipment
- FSAS III · Wire saws and wafer slicing equipment
- ONYX 3200 · Film composition analysis (XRF/FTIR)
- TFXRD Lab · Film composition analysis (XRF/FTIR)
- TXRF 3760 · Surface analysis instruments (XPS/SIMS)
- TXRF-V310 · Contamination analysis equipment
- WaferX 310 · Film composition analysis (XRF/FTIR)
Sources
Last updated: November 13, 2026