UTS-2000 series
JASCO's Fourier transform interferometric film thickness measurement system. It measures film (substrate) thickness from 0.25 to 750 µm nondestructively and without contact, and is used to measure epitaxial films and substrate thickness.
Maker: JASCO · Official product page
- Free to useQuotes and inquiries are free of charge
- Phone number is optionalYou can send the form without it
How it works
- Fill in the form and send itEnter your company name, contact name, email address and request. Phone, quantity and timing are optional.
- Semirai forwards your requestSemirai receives your request and forwards it to JASCO. Your details are shared with the maker only with your consent.
- The maker repliesReplies usually arrive within 2–3 business days.
Can't find a product, or unsure which to choose?
Free consultationSpecifications
| Type | Fourier transform interferometric film thickness measurement (reflection; transmission is optional) |
|---|---|
| Thickness range | 0.25 to 750 µm (Si, near-infrared measurement) / 0.7 to 750 µm (Si, mid-infrared measurement) |
| Repeatability | 0.005 µm or less (same point, Si) |
| Stage | 200 x 200 mm (drive resolution 2 µm) |
| Main applications | Thickness measurement of epitaxial films, substrates, etch residues and more |
Specifications as published by the maker. See the sources below.
Overview
The UTS-2000 series is JASCO's film thickness measurement system. It applies spectroscopic analysis technology to measure film (substrate) thickness nondestructively and without contact. JASCO says a high-precision interferometer and high-throughput optics allow precise measurement over a range of 0.25 to 750 µm.
The measurement method is Fourier transform interferometry, with reflection measurement as standard and transmission measurement as an option. The measurement area is 20 x 20 to 500 x 500 µm on the microscope model and φ2, 3, 4 and 6 mm on the macro model. The thickness range on Si is 0.25 to 750 µm with near-infrared measurement and 0.7 to 750 µm with mid-infrared measurement, and repeatability at the same point is 0.005 µm or less (Si).
The standard auto stage (200 x 200 mm, drive resolution 2 µm) allows evaluation of in-plane thickness distribution. Options include cassette-to-cassette automatic transfer, and it supports FOUP openers and multiple load ports for process use, as well as SEMI standards.
Key features
- Wide measurement range of 0.25 to 750 µm, nondestructive and non-contact
- Repeatability at the same point of 0.005 µm or less (Si)
- Supports automatic transfer systems, FOUP openers and multiple load ports
- Options include wavelength extension, a transmission measurement system that quantifies light-element impurities in Si, and data analysis software that quantifies carrier concentration
Applications
- Thickness measurement of epitaxial films, substrates, etch residues and more
- Evaluation of in-plane thickness distribution on devices
- From process use to development and evaluation
FAQ
Can it measure diffusion layers with unclear interfaces?
The official site says the optional wavelength extension makes it possible to measure diffusion layers with unclear interfaces.
Terms explained
Uniformity (Within-Wafer and Wafer-to-Wafer) · Ellipsometry (Spectroscopic Ellipsometry)
Other film thickness metrology
- HyperGauge C17319-11 · Hamamatsu Photonics
- Optical NanoGauge C12562-03 · Hamamatsu Photonics
- Xtrology · HORIBA
- K-MSX · Kowa Thermo Technologies & Products
- GS-300 · Otsuka Electronics
- OPTM series · Otsuka Electronics
- XHEMIS EX-2000 · Rigaku
- VM-1020 · SCREEN Holdings
More from JASCO
- FT/IR-4X · Organic analysis instruments
- NRS-5500/7500 · Organic analysis instruments
Sources