FSAS II
Rigaku's automatic X-ray system for measuring wafer crystal orientation. It automatically measures the cut angle of the wafer's main surface and the position of the orientation flat or notch.
Maker: Rigaku · Official product page
- Free to useQuotes and inquiries are free of charge
- Phone number is optionalYou can send the form without it
How it works
- Fill in the form and send itEnter your company name, contact name, email address and request. Phone, quantity and timing are optional.
- Semirai forwards your requestSemirai receives your request and forwards it to Rigaku. Your details are shared with the maker only with your consent.
- The maker repliesReplies usually arrive within 2–3 business days.
Can't find a product, or unsure which to choose?
Free consultationSpecifications
| Type | Crystal orientation measurement by X-ray (vacuum chuck holding, automatic scans at 0°/90°/180°/270°) |
|---|---|
| 2θ setting (measurement plane) | Si (111), (110), (100), (211), (511) |
| Sample size | φ200 mm or φ300 mm wafers with OF or notch |
| Operation | Touch-panel PC |
Specifications as published by the maker. See the sources below.
Overview
FSAS II is Rigaku's automatic X-ray system for measuring wafer crystal orientation. It automatically measures the cut angle of the wafer's main surface and the position of the OF (orientation flat) or notch.
A vacuum chuck holds the sample, and the system scans automatically at each in-plane rotation position of 0°, 90°, 180° and 270° to detect peak positions. It calculates and outputs the deviation angles in the X and Y directions relative to the wafer's cut surface.
It is operated from a touch-panel PC, and Rigaku says automatic measurement and calculation eliminate human measurement error. It handles φ200 mm or φ300 mm wafers with an OF or notch.
Key features
- Peak detection by vacuum chuck holding and automatic scans in 4 in-plane directions
- Automatic calculation of X and Y deviation angles relative to the cut surface
- Automatic measurement and calculation eliminate human measurement error
- Supports Si (111), (110), (100), (211) and (511) measurement planes
Applications
- Measurement of the cut angle (plane orientation) of silicon wafer main surfaces
- Measurement of orientation flat and notch positions
FAQ
Which wafer sizes can FSAS II measure?
According to the official page, it handles φ200 mm or φ300 mm wafers with an OF or notch.
Terms explained
Light Point Defect (LPD) · Photoluminescence (PL) · X-ray Diffraction (XRD) · Raman Spectroscopy
Other wafer substrate inspection equipment
- EPM-2200 · Kobelco Research Institute
- LEP series · Kobelco Research Institute
- SBW series flatness and shape measurement systems · Kobelco Research Institute
- MAGICS M5640 · Lasertec
- EC-80 · Napson
- NC-6800FLA · Napson
- NC-80MAP · Napson
- PN-12α · Napson
All wafer substrate inspection equipment and Japanese suppliers
More from Rigaku
- AZX 400 · Film composition analysis (XRF/FTIR)
- FSAS III · Wire saws and wafer slicing equipment
- ONYX 3200 · Film composition analysis (XRF/FTIR)
- TFXRD Lab · Film composition analysis (XRF/FTIR)
- TXRF 3760 · Surface analysis instruments (XPS/SIMS)
- TXRF-V310 · Contamination analysis equipment
- WaferX 310 · Film composition analysis (XRF/FTIR)
- WDA-3650 · Film composition analysis (XRF/FTIR)
Sources
Wafer substrate inspection equipment
Last updated: November 13, 2026