XRTmicron
Rigaku's high-resolution X-ray topography imaging system (Lab configuration). It detects crystal defects such as dislocations non-destructively and handles samples up to 300 mm in diameter.
Maker: Rigaku · Official product page
- Free to useQuotes and inquiries are free of charge
- Phone number is optionalYou can send the form without it
How it works
- Fill in the form and send itEnter your company name, contact name, email address and request. Phone, quantity and timing are optional.
- Semirai forwards your requestSemirai receives your request and forwards it to Rigaku. Your details are shared with the maker only with your consent.
- The maker repliesReplies usually arrive within 2–3 business days.
Can't find a product, or unsure which to choose?
Free consultationSpecifications
| Type | X-ray topography imaging (switchable between transmission and reflection) |
|---|---|
| X-ray source | MicroMax-007 (high-brightness, 2-wavelength) + parabolic multilayer mirror |
| Detector | XTOP (5.4 µm/pixel), HR-XTOP (2.4 µm/pixel, optional), HyPix-3000HE (100 µm/pixel) |
| Samples | Test coupons to wafers up to 300 mm, ingots and others (manual handling) |
Specifications as published by the maker. See the sources below.
Overview
XRTmicron (Lab) is Rigaku's high-resolution X-ray topography imaging system. It combines a high-brightness micro X-ray source, special X-ray mirror optics and a high-resolution X-ray camera, and Rigaku says it shortens measurement time by about an order of magnitude compared with conventional systems.
It detects crystal defects such as dislocations, threading dislocations to the surface and defects in epitaxial layers non-destructively. It applies to a range of single-crystal materials, including Si, SiC, GaN, Ge, GaAs, quartz crystal, LN, LT and sapphire.
Samples up to 300 mm in diameter, including test coupons, full wafers, epitaxial layers on wafers and crystal ingots, are loaded by manual handling. The configuration is aimed at research on crystal growth and epitaxial layers.
Key features
- Switches between transmission and reflection topography in one system
- Horizontal sample holder that applies no external force other than gravity
- Defect visualization with automatic wafer bow correction
- Automatic control from alignment to image acquisition, and automatic dislocation mapping
Applications
- Crystal defect evaluation of single-crystal wafers such as SiC and GaN
- Defect detection in epitaxial layers
- Defect analysis of crystal ingots
FAQ
How are samples loaded on XRTmicron (Lab)?
According to the official specifications, wafer transfer and sample handling are manual. A separate Near-Fab configuration supports automatic wafer transfer.
Other crystal defect inspection equipment
- PLATO Series · HORIBA
- GALOIS211 · Lasertec
- SICA108 · Lasertec
- SICA88 · Lasertec
- XS-1 Sirius · Mipox Corporation
- XTRAIA XT-3000 · Rigaku
- INSPECTRA® PL Series · Toray Engineering
All crystal defect inspection equipment and Japanese suppliers
More from Rigaku
- AZX 400 · Film composition analysis (XRF/FTIR)
- FSAS II · Wafer substrate inspection equipment
- FSAS III · Wire saws and wafer slicing equipment
- ONYX 3200 · Film composition analysis (XRF/FTIR)
- TFXRD Lab · Film composition analysis (XRF/FTIR)
- TXRF 3760 · Surface analysis instruments (XPS/SIMS)
- TXRF-V310 · Contamination analysis equipment
- WaferX 310 · Film composition analysis (XRF/FTIR)
Sources
Crystal defect inspection equipment
Last updated: November 13, 2026