Pass Box
A pass box is a box-shaped transfer port with a door on each side, built into a cleanroom wall. It lets parts, documents and tools pass between rooms of different cleanliness without anyone walking through. Every trip a person makes through the air shower takes time and risks bringing in dirt, so materials get their own route.
Also called: pass-through box, pass-through chamber
Diagram
How it works
An item is placed in through the outer door, the door is closed, and the item is taken out through the inner door. The two doors are interlocked so they never open at the same time, preventing outside air from flowing into the cleanroom.
Dynamic pass boxes contain a HEPA filter and fan and blow clean air through the box to remove dust from the item's surface. Some also have ultraviolet lamps for sterilisation. A plain box without filtration is called a static pass box.
Use in semiconductor fabs
Before an item goes into a pass box, outer packaging is usually removed and surfaces are wiped with alcohol so contamination is not carried in.
In a semiconductor fab, wafers themselves move in sealed FOUPs on automated transport, not through pass boxes. Pass boxes are used for replacement parts, jigs, consumables and similar materials.
Japanese companies involved
- Airtech Japan makes pass boxes and air showers for cleanrooms.
- Nippon Muki makes HEPA filters and cleanroom equipment.
- Airtech Japan · Cleanrooms, clean benches, air showers and FFUs
- Nippon Muki · HEPA, ULPA and chemical filters and cleanroom equipment
FAQ
How does a pass box differ from an air shower?
An air shower is the entrance for people and blows dust off their garments. A pass box is only for materials, and no one goes through it. Separating the routes for people and materials reduces the number of entries and the contamination carried in.
What is a dynamic pass box?
It is a pass box with a built-in HEPA filter and fan that keeps clean air flowing through the box. After an item is placed inside, the air flow removes surface dust and restores the cleanliness of the box before the inner door is opened.
Related pages
Sources
Fab infrastructure and equipment parts terms