Point of Use (POU)

Point of use (POU) is the place where a gas, chemical or ultrapure water is actually consumed: the supply inlet at or just before a process tool. It is the last point before the fluid reaches the wafer, so fabs treat it as the reference point at which purity is measured and guaranteed.

Also called: POU, use point

Diagram


Point of use tasks: water quality measurement, filters and abatement

Click anywhere to zoom in there. Scroll to zoom, drag to move

Keeping the quality made centrally all the way to where it is used.

Why quality is judged at the point of use


Fluids are produced in central plants and travel through long pipes to the tools. Along the way purity can fall. Ultrapure water may pick up material leached from pipe walls, bacteria can grow in places where water stands still, and particles can be shed by valves and fittings. Water quality is therefore measured and guaranteed at the point of use, not at the outlet of the purification plant.

Gases and chemicals follow the same logic. POU filters and POU purifiers are fitted just before the tool to catch particles, moisture and metal impurities picked up in the distribution system. They are the last line of defence before the fluid reaches the wafer.

Point-of-use abatement


The idea also applies to exhaust. Tools that use toxic or flammable gases are fitted with POU abatement units, placed right next to the tool or in the subfab below it, that treat the exhaust before it enters the central exhaust ducts. Treating gas close to its source avoids leaks in long ducts and keeps solids from forming inside them.

As devices shrink and purity requirements rise, controlling quality and safety at the point of use becomes more important.

Japanese companies involved


  • Kurita Water Industries, Organo and Nomura Micro Science build ultrapure water systems, including the final polishing stages close to where the water is used.
  • Kanken Techno makes abatement systems placed at individual process tools.

FAQ


What does point of use mean?

It is the place where a fluid is actually used. In a fab it is the connection at the process tool where gases, chemicals or ultrapure water enter the tool, as opposed to the central plant where they are produced or stored.

What is a POU filter?

A filter installed immediately before the tool or inside it, on a gas, chemical or water line. It removes particles and, in purifier versions, moisture or metal impurities that the fluid picked up between the central supply and the tool.