MFC gas conversion factor (GCF) calculator

Plasma, vacuum, films and facilities. Everything is calculated in your browser; nothing you enter is sent to a server.

KEY POINTS

A thermal MFC measures flow by the heat a gas carries, so gases with different specific heat and density read incorrectly. With an N₂-calibrated MFC, actual flow is reading × GCF: to flow 100 sccm of SiH₄ (GCF about 0.60), set about 167 sccm. C₄F₈ and SF₆, with GCFs around 0.2, can flow only about one-fifth of the N₂ full scale.

Converting between calibration gas and process gas

Actual flow of the process gas60.00sccm
Conversion ratio GCF(process gas) / GCF(calibration gas)0.6000
Setpoint for 200 sccm of process gas333.33sccm (in calibration gas)
Full scale in process gas300.0sccm

The factors are typical values commonly used for thermal MFCs. They differ by a few percent between makers and sensor designs, so for accuracy use the MFC maker's factor table or actual-gas calibration (multi-gas, multi-range functions).

Conversion factor for a two-component mixture

GCF of the mixture0.9375

Estimating the conversion factor from physical properties

Estimated GCF0.598

Defaults are for SiH₄ (density 1.433 g/L, cp 0.3189 cal/g·K) and give a value close to the table's 0.60. Use this to estimate a rough factor for gases not in the table.

Gas conversion factors

GasGCF (N₂ = 1)Actual flow limit on an N₂ 500 sccm range
N₂ nitrogen1.000500 sccm
Ar argon1.390695 sccm
He helium1.450725 sccm
H₂ hydrogen1.010505 sccm
O₂ oxygen0.993497 sccm
Air1.000500 sccm
CO₂ carbon dioxide0.700350 sccm
N₂O nitrous oxide0.710355 sccm
NH₃ ammonia0.730365 sccm
CH₄ methane0.720360 sccm
SiH₄ silane0.600300 sccm
SiH₂Cl₂ dichlorosilane0.400200 sccm
Cl₂ chlorine0.860430 sccm
HCl hydrogen chloride1.000500 sccm
HBr hydrogen bromide1.000500 sccm
BCl₃ boron trichloride0.410205 sccm
CF₄ carbon tetrafluoride0.420210 sccm
CHF₃ trifluoromethane0.500250 sccm
C₂F₆ hexafluoroethane0.240120 sccm
C₄F₈ octafluorocyclobutane0.16482 sccm
SF₆ sulfur hexafluoride0.260130 sccm
NF₃ nitrogen trifluoride0.480240 sccm
WF₆ tungsten hexafluoride0.250125 sccm
Xe xenon1.320660 sccm

Why thermal MFCs need conversion factors

A thermal MFC heats the sensor tube the gas flows through and measures the heat carried by the gas from the temperature difference upstream and downstream. At the same mass flow, gases with different specific heat and density carry different amounts of heat, so an MFC calibrated with nitrogen reads incorrectly with other gases. Polyatomic molecules with high specific heat (SiH₄, CF₄, C₄F₈ and others) carry more heat at the same flow, so their GCF is below 1.

Tool recipes are written in actual gas flow, so with an N₂-calibrated MFC the setpoint must be the desired flow divided by the GCF. For gases such as C₄F₈ and SF₆, with a GCF around 0.2, only about one-fifth of the N₂ full scale can flow. Modern MFCs store the characteristics of many gases and convert automatically once the gas is selected.

FAQ


How do I convert an N₂ MFC setpoint for another gas?

Divide the desired process gas flow by the gas's GCF. For example, 100 sccm of SiH₄ with a GCF of 0.60 needs a setpoint of about 167 sccm.

How is the GCF of a gas mixture calculated?

GCF_mix = 100 / Σ(a_i / GCF_i), where a_i is each component's volume percent.