Exhibiting at SEMICON Japan 2026 (Dec 9–11)? We are now accepting advertising inquiries from exhibitors.Ads for SEMICON Japan 2026Learn more

Comparison · Lithography

High-NA EUV vs standard EUV: what is the difference?

Both generations come from ASML, which sells standard EUV scanners on its NXE platform and High-NA scanners on its EXE platform, with mirror optics made by ZEISS. Standard EUV has been in volume production since 2019. High-NA systems have since been delivered to leading chipmakers and research centres for development and qualification. The question for chipmakers is which layers justify the move from 0.33 to 0.55 NA, and when.

The short answer


The difference is the numerical aperture (NA) of the projection optics. Standard EUV scanners use NA 0.33 and print down to roughly 13 nm half-pitch in one exposure; High-NA EUV uses NA 0.55, about 1.7 times higher, and reaches roughly 8 nm half-pitch with the same 13.5 nm light. The gain comes with anamorphic optics that halve the exposure field, a shallower depth of focus and new demands on masks and resists.

Side-by-side comparison


AspectHigh-NA EUVStandard EUV
Numerical aperture0.550.33
Wavelength13.5 nm (unchanged)13.5 nm
Approximate single-exposure half-pitchAbout 8 nmAbout 13 nm
ASML platformEXENXE
Reduction ratioAnamorphic: 4x in one direction, 8x in the other4x in both directions
Full exposure field at the wafer26 × 16.5 mm (half field)26 × 33 mm
Depth of focusShallower, so wafers, masks and resist films must be flatter and thinnerLarger process window for the same feature type
MaskSame 6-inch mask format, but layouts are drawn for the anamorphic ratio; large dies need stitching across two fieldsExisting EUV mask infrastructure and design flows
Production statusFirst systems installed for development and early process qualificationHigh-volume production at leading logic and DRAM makers since 2019

Why a higher NA gives finer patterns


The Rayleigh criterion, R = k₁ × λ / NA, links resolution to wavelength and numerical aperture. Since the wavelength stays at 13.5 nm, the only remaining lever is NA. Raising it from 0.33 to 0.55 improves resolution by a factor of 0.55/0.33, about 1.67. For a k₁ of around 0.33, this moves the printable half-pitch from roughly 13 nm to roughly 8 nm.

A higher NA means the optics collect light over wider angles, which requires much larger mirrors in the projection system. ZEISS builds these optics, and the EXE scanner is physically larger than an NXE tool.

Anamorphic optics and the half field


If High-NA optics kept the usual 4x reduction in both directions, light would strike the reflective mask at angles too steep for its multilayer coating to reflect well. ASML and ZEISS therefore chose anamorphic optics: 4x reduction in one direction and 8x in the other. Mask patterns are drawn twice as large in the 8x direction, which keeps the mask size standard but halves the field printed on the wafer, from 26 × 33 mm to 26 × 16.5 mm.

Chips that fit within a half field are unaffected apart from needing more exposures per wafer, which ASML offsets with faster wafer and mask stages. Larger dies, such as big AI accelerators, must be split across two fields and stitched together, which affects chip design as well as the process.

What else has to change around the scanner


Depth of focus falls roughly with the square of NA, so High-NA leaves less room for wafer topography and requires thinner resist films. Thinner films absorb fewer photons, which makes stochastic effects such as line-edge roughness and random missing or bridged features harder to control. This is one reason metal oxide resists, which absorb EUV more strongly than organic resists, attract attention for High-NA layers.

Masks, pellicles, metrology and computational lithography all need updating for the new optics and field size. The economic case rests on replacing standard-EUV double patterning on the tightest layers with a single High-NA exposure.

Which to use when


Standard 0.33 NA EUV remains the main tool for critical layers at current leading-edge nodes and will stay in use for many layers even after High-NA arrives. High-NA is aimed at the few layers where standard EUV would need two or more exposures. Chipmakers have announced different adoption timings, and each compares the cost of a High-NA single exposure with that of standard-EUV multi-patterning for its own designs.

FAQ


Does High-NA EUV use a different wavelength?

No. Both use 13.5 nm light from a tin plasma source. The difference lies entirely in the projection optics, whose numerical aperture rises from 0.33 to 0.55, and in the changes that follow from it: anamorphic reduction, a half-size field and a shallower depth of focus.

Can standard EUV masks be used on a High-NA scanner?

The physical mask format remains a 6-inch square plate, but the pattern must be laid out for the 4x/8x anamorphic reduction and the half-size field, so masks are made specifically for High-NA layers. Optimised absorber materials are also being studied to suit the different illumination angles.

Is EUVL the same as High-NA EUV?

EUVL, extreme ultraviolet lithography, is the general name for lithography at 13.5 nm and covers both generations. High-NA EUV refers specifically to the 0.55 NA systems; the 0.33 NA tools are sometimes called low-NA or standard EUV.

Will there be an EUV generation beyond 0.55 NA?

ASML has publicly discussed a possible hyper-NA generation with an NA above 0.7, but it remains a study rather than a product. Its feasibility depends on optics, polarisation effects at very high angles, resists and, above all, whether the cost per layer can compete.

Terms compared


Japanese companies involved


More lithography comparisons


Sources


  1. ZEISS SMT: High-NA-EUV Lithography: the next EUV generation
  2. ASML: EUV lithography systems
  3. ASML: The Rayleigh criterion for resolution
  4. ASML: Lenses & mirrors - Lithography principles

More on this topic


Semiconductor comparisons

Lithography terms

Last updated: November 2, 2026