High-NA EUV vs standard EUV: what is the difference?
Both generations come from ASML, which sells standard EUV scanners on its NXE platform and High-NA scanners on its EXE platform, with mirror optics made by ZEISS. Standard EUV has been in volume production since 2019. High-NA systems have since been delivered to leading chipmakers and research centres for development and qualification. The question for chipmakers is which layers justify the move from 0.33 to 0.55 NA, and when.
The short answer
The difference is the numerical aperture (NA) of the projection optics. Standard EUV scanners use NA 0.33 and print down to roughly 13 nm half-pitch in one exposure; High-NA EUV uses NA 0.55, about 1.7 times higher, and reaches roughly 8 nm half-pitch with the same 13.5 nm light. The gain comes with anamorphic optics that halve the exposure field, a shallower depth of focus and new demands on masks and resists.
Side-by-side comparison
| Aspect | High-NA EUV | Standard EUV |
|---|---|---|
| Numerical aperture | 0.55 | 0.33 |
| Wavelength | 13.5 nm (unchanged) | 13.5 nm |
| Approximate single-exposure half-pitch | About 8 nm | About 13 nm |
| ASML platform | EXE | NXE |
| Reduction ratio | Anamorphic: 4x in one direction, 8x in the other | 4x in both directions |
| Full exposure field at the wafer | 26 × 16.5 mm (half field) | 26 × 33 mm |
| Depth of focus | Shallower, so wafers, masks and resist films must be flatter and thinner | Larger process window for the same feature type |
| Mask | Same 6-inch mask format, but layouts are drawn for the anamorphic ratio; large dies need stitching across two fields | Existing EUV mask infrastructure and design flows |
| Production status | First systems installed for development and early process qualification | High-volume production at leading logic and DRAM makers since 2019 |
Why a higher NA gives finer patterns
The Rayleigh criterion, R = k₁ × λ / NA, links resolution to wavelength and numerical aperture. Since the wavelength stays at 13.5 nm, the only remaining lever is NA. Raising it from 0.33 to 0.55 improves resolution by a factor of 0.55/0.33, about 1.67. For a k₁ of around 0.33, this moves the printable half-pitch from roughly 13 nm to roughly 8 nm.
A higher NA means the optics collect light over wider angles, which requires much larger mirrors in the projection system. ZEISS builds these optics, and the EXE scanner is physically larger than an NXE tool.
Anamorphic optics and the half field
If High-NA optics kept the usual 4x reduction in both directions, light would strike the reflective mask at angles too steep for its multilayer coating to reflect well. ASML and ZEISS therefore chose anamorphic optics: 4x reduction in one direction and 8x in the other. Mask patterns are drawn twice as large in the 8x direction, which keeps the mask size standard but halves the field printed on the wafer, from 26 × 33 mm to 26 × 16.5 mm.
Chips that fit within a half field are unaffected apart from needing more exposures per wafer, which ASML offsets with faster wafer and mask stages. Larger dies, such as big AI accelerators, must be split across two fields and stitched together, which affects chip design as well as the process.
What else has to change around the scanner
Depth of focus falls roughly with the square of NA, so High-NA leaves less room for wafer topography and requires thinner resist films. Thinner films absorb fewer photons, which makes stochastic effects such as line-edge roughness and random missing or bridged features harder to control. This is one reason metal oxide resists, which absorb EUV more strongly than organic resists, attract attention for High-NA layers.
Masks, pellicles, metrology and computational lithography all need updating for the new optics and field size. The economic case rests on replacing standard-EUV double patterning on the tightest layers with a single High-NA exposure.
Which to use when
Standard 0.33 NA EUV remains the main tool for critical layers at current leading-edge nodes and will stay in use for many layers even after High-NA arrives. High-NA is aimed at the few layers where standard EUV would need two or more exposures. Chipmakers have announced different adoption timings, and each compares the cost of a High-NA single exposure with that of standard-EUV multi-patterning for its own designs.
FAQ
Does High-NA EUV use a different wavelength?
No. Both use 13.5 nm light from a tin plasma source. The difference lies entirely in the projection optics, whose numerical aperture rises from 0.33 to 0.55, and in the changes that follow from it: anamorphic reduction, a half-size field and a shallower depth of focus.
Can standard EUV masks be used on a High-NA scanner?
The physical mask format remains a 6-inch square plate, but the pattern must be laid out for the 4x/8x anamorphic reduction and the half-size field, so masks are made specifically for High-NA layers. Optimised absorber materials are also being studied to suit the different illumination angles.
Is EUVL the same as High-NA EUV?
EUVL, extreme ultraviolet lithography, is the general name for lithography at 13.5 nm and covers both generations. High-NA EUV refers specifically to the 0.55 NA systems; the 0.33 NA tools are sometimes called low-NA or standard EUV.
Will there be an EUV generation beyond 0.55 NA?
ASML has publicly discussed a possible hyper-NA generation with an NA above 0.7, but it remains a study rather than a product. Its feasibility depends on optics, polarisation effects at very high angles, resists and, above all, whether the cost per layer can compete.
Terms compared
- High-NA EUV LithographyNext-generation EUV lithography that raises the numerical aperture from 0.33 to 0.55 to print finer patterns in a single exposure.
- EUV (Extreme Ultraviolet)Light with a 13.5 nm wavelength used to print the finest chip patterns; it needs mirrors, vacuum and a tin-plasma light source.
- Reticle / PhotomaskThe mask used in reduction projection lithography: a pattern four times larger than on the wafer, one reticle per layer.
Japanese companies involved
- Lasertec · EUV mask and mask blank inspection
- JSR · Photoresists and semiconductor materials
- Shin-Etsu Chemical · Silicon wafers, photoresists and photomask blanks
- Tokyo Ohka Kogyo (TOK) · Photoresists and high-purity process chemicals
- HOYA · Mask blanks (including EUV) and photomasks
- AGC · EUV mask blanks and glass materials
- Mitsui Chemicals · EUV pellicles and wafer protection tapes
- Rapidus · Leading-edge logic foundry (2 nm, in development)
More lithography comparisons
Sources
Semiconductor comparisons
- All semiconductor comparisons
- Single patterning vs multi-patterning: what is the difference?
- Chemically amplified resist vs metal oxide resist: what is the difference?
- ALD vs CVD: what is the difference?
- CVD vs PVD: what is the difference?
- PECVD vs LPCVD: what is the difference?
- MOCVD vs MBE: what is the difference?
- Dry etching vs wet etching: what is the difference?
Lithography terms
Last updated: November 2, 2026