Exhibiting at SEMICON Japan 2026 (Dec 9–11)? We are now accepting advertising inquiries from exhibitors.Ads for SEMICON Japan 2026Learn more

Test and reliability equipment

Failure analysis equipment4 Japanese makers

Failure analysis equipment locates the failure site in a defective device and traces it to its physical cause. Emission microscopy (EMMI) detects faint light from leakage sites, OBIRCH finds voids and high-resistance spots in wiring, and lock-in thermography detects hot spots.

9 products listed · 12 related categories
Get quotes (5 companies)Inquire (5 companies)

Tick "Add to bulk request" on the cards to send your request only to the companies and products you choose.

  • Free to useQuotes and inquiries are free of charge
  • Phone number is optionalYou can send the form without it
How it works
  1. Fill in one form and send itEnter your company name, contact name, email address and request. Phone, quantity and timing are optional.
  2. Semirai forwards your requestSemirai receives your request and forwards it to the 5 companies in this category. Your details are shared with them only with your consent.
  3. The companies replyEach company usually replies within 2–3 business days.

AdBanner space for Failure analysis equipment is available (one company per category).About advertising →

Hamamatsu Photonics

Dual PHEMOS®-X C16506-01

A high-resolution emission microscope from Hamamatsu Photonics that performs failure analysis from both the front side and the back side of a wafer or die. It switches between front-side and back-side analysis of advanced 3D devices without moving them to another analysis system.

Analysis directionBoth front side and back side
Optical stage travel (front side)X 40 mm / Y 40 mm / Z 80 mm
Optical stage travel (back side)X 60 mm / Y 60 mm / Z 20 mm
Sample stage (MPd-1000X)X 300 mm / Y 300 mm / Z 22.5 mm / θ ±5°
WeightApprox. 2,335 kg
Hamamatsu Photonics

iPHEMOS®-DDX C18040-11

An inverted emission microscope for failure analysis of 2.5D/3D packages such as AI chiplets and HBM, and of large packages. It docks directly with a tester from 3 directions and combines 7 analysis techniques in one system.

TypeInverted emission microscope
Integrated techniquesPEM, Thermal/LIT, LSM, OBIRCH, DALS, EOP/EOFM, TD Imaging
Tester dockingDirect docking from 3 directions
Optical stage travelX 60 mm / Y 60 mm / Z 20 mm
Power consumptionApprox. 3300 VA
Hamamatsu Photonics

iPHEMOS-MPX C10506-07-06

A high-resolution inverted emission microscope from Hamamatsu Photonics that locates failures in semiconductor devices by capturing the light emission and heat that accompany them. A multi-wavelength laser covers visible to near-infrared light in one system.

TypeInverted emission microscope
CamerasUp to 2 ultra-high-sensitivity cameras
Light sourceUp to 4 for OBIRCH, DALS, EOP and laser marker
Objective lensesUp to 10, plus a high-sensitivity macro lens
Optical stage travelX 60 mm / Y 60 mm / Z 20 mm
Hamamatsu Photonics

PHEMOS-X emission microscope C15765-01

A high-resolution emission microscope that locates failures by capturing light emission and heat caused by defects. It performs emission and thermal analysis with ultra-high-sensitivity cameras and light sources for OBIRCH, DALS and EOP.

Analysis techniqueEmission analysis, thermal analysis, OBIRCH
TargetSemiconductor devices
Related modelsDual PHEMOS-X C16506-01 (analysis from both front and back)
Main applicationsLocating failures (narrowing down the position)
Hamamatsu Photonics

Solid Cold® Emmi-X Camera

An emission analysis camera for semiconductor failure analysis that uses Solid Cold cooling (linear cooling). The company says it needs no LN₂ and supports stable emission analysis 24 hours a day.

Cooling methodSolid Cold cooling (linear cooling), no LN₂ required
Sensor1k × 1k
ReliabilityMTTF 90 000 hours
Wavelength switchingAbout 5 s (1-axis filter, gearless structure)
Hitachi High-Tech

NanoProber® NP8000

A nano-device characterization system that lands probes on devices under SEM observation to measure transistor electrical characteristics. It is designed for the 5 nm node and beyond.

Analysis techniqueNanoprobing (electrical characteristics, EBAC, EBIC, pulsed IV)
TargetTransistors and wiring (5 nm node and beyond)
Key featureNew Schottky electron gun gives clear images even at ultra-low accelerating voltages below 100 V
Main applicationsElectrical identification of defective transistors
JEOL

HAXIS LIM

An SEM-based semiconductor failure analysis platform that combines delayering by low-angle Ar ion milling (LIM) with passive voltage contrast (PVC) observation.

ConfigurationLow-angle ion milling (LIM) + SEM (JSM-IT810)
Milling area2,500 μm diameter or more
Ion acceleration voltage2 to 10 kV (ion energy 2 to 10 keV)
GasArgon gas
VC filterNegative voltage of -50 to 0 V in 0.1 V steps
JEOL

LazEdge

A laser processing SEM system that combines a JEOL SEM with laser technology from Hamamatsu Photonics. A femtosecond laser cuts cross sections inside the specimen chamber, so samples are observed and analyzed without air exposure.

ConfigurationSEM + femtosecond laser processing (Hamamatsu Photonics technology)
TypeCross-section processing inside the specimen chamber with a femtosecond laser using spatial phase modulation
Main applicationsSemiconductor failure analysis that needs fast cross-section processing, battery and metal analysis
Processing exampleCross section of a Mo plate in about 30 minutes
Lasertec

OPTELICS IR

Lasertec's IR confocal microscope. Its confocal optics with high-brightness infrared illumination observe and measure the inside of IR-transmitting materials such as silicon wafers, nondestructively and without contact.

TypeHigh-brightness IR confocal optics
Observation wavelength1000–1500 nm
MeasurementXY measurement, height measurement by optical sectioning along the Z axis
Main applications3D packaging evaluation and inspection, internal failure analysis of advanced packaging devices, bonding misalignment measurement and more

* Specifications are reference values based on public information. Please confirm exact specifications with the maker.

Other test and reliability equipment


Key terms


X-ray Absorption Near Edge Structure (XANES) · Chemical Shift (XPS) · X-ray Photoelectron Spectroscopy (XPS) · Focused Ion Beam (FIB) · Energy Dispersive X-ray Spectroscopy (EDX / EDS) · OBIRCH (Optical Beam Induced Resistance Change)

Sources


  1. Hamamatsu Photonics: Dual PHEMOS-X C16506-01 product page
  2. Hamamatsu Photonics: iPHEMOS-DDX C18040-11 product page
  3. Hamamatsu Photonics: iPHEMOS-MPX C10506-07-06 product page
  4. Hamamatsu Photonics: PHEMOS-X C15765-01 product page
  5. Hamamatsu Photonics: Solid Cold Emmi-X camera product page
  6. Hitachi High-Tech: NP8000 product page
  7. JEOL: HAXIS LIM product page
  8. JEOL: LazEdge product page
  9. Lasertec: OPTELICS IR product page

More on this topic


Japanese equipment by category

Failure analysis equipment

Last updated: November 13, 2026